1
1.5 kV (built-in)
Telnet Console
Web Console (HTTP/HTTPS)
Windows Utility
ARP
BOOTP
DHCP Client
DNS
HTTP
HTTPS
ICMP
IPv4
LLDP
RFC2217
Rtelnet
PPP
SLIP
SMTP
SNMPv1/v2c
TCP/IP
Telnet
UDP
IGMP v1/v2c
Windows 11/10/8.1/8/7/Vista/XP/ME/98/95
Windows Server 2022/2019/2016/2012 R2/2012/2008 R2/2008/2003
Windows Embedded CE 6.0/5.0, Windows XP Embedded
Kernel versions 6.x, 5.x, 4.x, 3.x, 2.6.x, and 2.4.x
macOS Versions: 11.x, 10.12 to 10.15
Linux Kernel 5.x/4.x
VMWare ESXi (Windows 11/10)
VMware Fusion (Windows on macOS 10.12 to 11.x)
Parallels Desktop (Windows on macOS 10.12 to 11.x)
Android 3.1.x and later
SNTP
Local database
HTTPS
AES-128
RSA-1024
SHA-1
SHA-256
HTTPS (TLS 1.2)
SNMPv3
8-pin RJ45
8 or 16 ports
NPort 5610 Models: RS-232
NPort 5630 Models: RS-422, RS-485
NPort 5650 Models: RS-232, RS-422, RS-485
Disabled
Ethernet Modem
Pair Connection
Real COM
Reverse Telnet
RFC2217
TCP Client
TCP Server
UDP
Supports standard baudrates (unit=bps): 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k
5, 6, 7, 8
1, 1.5, 2
None, Even, Odd, Space, Mark
None
RTS/CTS (RS-232 only)
DTR/DSR (RS-232 only)
XON/XOFF
1 kilo-ohm, 150 kilo-ohms
120 ohms
Automatic Data Direction Control (ADDC)
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Tx+, Tx-, Rx+, Rx-, GND
Tx+, Tx-, Rx+, Rx-, GND
Data+, Data-, GND
NPort 5610-8-48V/16-48V: 135 mA @ 48 VDC
NPort 5650-8-HV-T/16-HV-T: 152 mA @ 88 VDC
NPort 5610-8/16: 141 mA @ 100 VAC
NPort 5630-8/16: 152 mA @ 100 VAC
NPort 5650-8/8-T/16/16-T: 158 mA @ 100 VAC
NPort 5650-8-M-SC/16-M-SC: 174 mA @ 100 VAC
NPort 5650-8-S-SC/16-S-SC: 164 mA @ 100 VAC
HV Models: 88 to 300 VDC
AC Models: 100 to 240 VAC, 47 to 63 Hz
DC Models: ±48 VDC, 20 to 72 VDC, -20 to -72 VDC
Built-in WDT
Metal
19-inch rack mounting
480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
NPort 5650-16-HV-T: 3,820 g (8.42 lb)
NPort 5650-8-HV-T: 3,720 g (8.20 lb)
NPort 5610-16-48V: 3,260 g (7.19 lb)
NPort 5610-8-48V: 3,160 g (6.97 lb)
NPort 5630-16: 2,560 g (5.64 lb)
NPort 5630-8/5650-16/5650-16-T: 2,510 g (5.53 lb)
NPort 5650-16-S-SC: 2,500 g (5.51 lb)
NPort 5610-16: 2,490 g (5.49 lb)
NPort 5650-8-S-SC/5650-16-M-SC: 2,440 g (5.38 lb)
NPort 5610-8: 2,290 g (5.05 lb)
NPort 5650-8-M-SC: 2,380 g (5.25 lb)
NPort 5650-8/5650-8-T: 2,310 g (5.09 lb)
LCD panel display (standard temp. models only)
Push buttons for configuration (standard temp. models only)
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
High-voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Standard Models: -20 to 70°C (-4 to 158°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
High-voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
EN 55032/35
CISPR 32, FCC Part 15B Class A
NPort 5650-8/16 Models:
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2.5 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8
IEC 61000-4-11
NPort 5650-8/16-HV Models:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8
UL 62368-1
EN 55011: 2007+A2: 2007 Class A (Group 1) compliant
EN 60601-1-2: 2007 compliant
NPort 5610-8: 903,009 hrs
NPort 5610-8-48V: 892,692 hrs
NPort 5630-8: 844,009 hrs
NPort 5650-8-T: 776,469 hrs
NPort 5650-8: 754,927 hrs
NPort 5650-8-M-SC/8-S-SC: 738,291 hrs
NPort 5650-8-HV-T: 716,168 hrs
NPort 5610-16-48V: 693,529 hrs
NPort 5610-16: 680,154 hrs
NPort 5630-16: 618,263 hrs
NPort 5650-16: 525,107 hrs
NPort 5650-16-T: 533,046 hrs
NPort 5650-16-M-SC/16-S-SC: 517,019 hrs
NPort 5650-16-HV-T: 506,093 hrs
HV Models: Telcordia (Bellcore) Standard TR/SR
All Other Models: MIL-HDBK-217F